Science and Technology
Paragraphs

Abstract

PURPOSE:

To provide the first national data on the nature, extent, and consequences of withholding among life science trainees.

METHOD:

In 2003, the authors surveyed 1,077 second-year doctoral students and postdoctoral fellows in life sciences at 50 U.S. universities, with a comparison group of trainees in computer science and chemical engineering. The study variables examined trainees' exposure to and the consequences of data withholding.

RESULTS:

Two hundred forty-six trainees (23.0%) reported that they had asked for and been denied access to information, data, materials, or programming associated with published research and 221 (20.6%) to unpublished research. Eighty-five trainees (7.9%) reported that they had denied another academic scientist's request(s) related to their own published research. Five hundred thirty-three trainees (50.8%) reported that withholding had had a negative effect on the progress of their research, 508 (48.5%) on the rate of discovery in their lab/research group, 472 (45.0%) on the quality of their relationships with academic scientists, 346 (33.0%) on the quality of their education, and 299 (28.5%) on the level of communication in their lab/research group. Trainees denied access to research were significantly more likely to report that data withholding had had a negative effect on several aspects of the educational experience.

CONCLUSIONS:

Data withholding had demonstrated negative effects on trainees. The life sciences, more so than chemical engineering or computer science, will have to address this issue among its trainees. Failure to do so could result in delayed research, inefficient training, and a culture of withholding among future life scientists.

All Publications button
1
Publication Type
Journal Articles
Publication Date
Journal Publisher
Academic Medicine
Authors
Eran Bendavid
Paragraphs

Several factors are changing the landscape of cervical cancer control, including a better understanding of the natural history of human papillomavirus (HPV), reliable assays for detecting high-risk HPV infections, and a soon to be available HPV-16/18 vaccine. There are important differences in the relevant policy questions for different settings. By synthesizing and integrating the best available data, the use of modeling in a decision analytic framework can identify those factors most likely to influence outcomes, can guide the design of future clinical studies and operational research, can provide insight into the cost-effectiveness of different strategies, and can assist in early decision-making when considered with criteria such as equity, public preferences, and political and cultural constraints

All Publications button
1
Publication Type
Journal Articles
Publication Date
Journal Publisher
Vaccine
Authors
Jeremy Goldhaber-Fiebert
Paragraphs

Objective:

To describe an academic medical center's experience with housestaff involvement in the implementation of a new clinical information system, with particular emphasis on resident contributions in tailoring the technology to meet the workflow needs of the center.

Methods:

A resident advisory group was formed to tailor the new system. Housestaff developed user interface screens to streamline presentation of patient data. Order sets were developed, offering an opportunity for education in standardized care and "best practice." A rounds report displays aggregated patient specific data for use in prerounding and rapid assessment of patient information. A sign-out tool was designed to facilitate transfer of information during change of shift.

Results:

Residents contributed in tailoring the technology to meet the workflow needs of our academic medical center setting.

Conclusion:

The design and implementation of a new clinical information system can be used to introduce concepts important in practice-based learning and systems-based practice.

All Publications button
1
Publication Type
Journal Articles
Publication Date
Journal Publisher
Journal of Clinical Outcomes Management
Authors
Paragraphs

HYPOTHESIS: A handheld wand-scanning device (1.5 lb, battery powered, 10 x 10 x 1.5 in) has been developed to detect commonly used surgical gauze sponges, which have been tagged with a radiofrequency identification (RFID) chip. We tested the hypothesis that this wand device has a successful detection rate of 100%, with 100% specificity and 100% sensitivity.

DESIGN: Prospective, blinded, experimental clinical trial.

SETTING: Stanford University Medical Center, Stanford, Calif.

PATIENTS: Eight patients undergoing abdominal or pelvic surgery.

INTERVENTIONS: Eight untagged sponges (1 control per patient) and 28 RFID sponges were placed in the patients. Just before closure, the first surgeon placed 1 RFID sponge (adult laparotomy tape; 18 x 18 in, 4-ply) in the surgical site, while the second surgeon looked away so as to be blinded to sponge placement. The edges of the wound were pulled together so that the inside of the cavity was not exposed during the detection experiments. The second (blinded) surgeon used the wand-scanning device to try to detect the RFID sponge.

MAIN OUTCOME MEASURES: A successful detection was defined as detection of an RFID sponge within 1 minute. We also administered a questionnaire to the surgeon and nurse involved in the detections to assess ease of use.

RESULTS: The RFID wand device detected all sponges correctly, in less than 3 seconds on average. There were no false-positive or false-negative results.

CONCLUSIONS: We found a detection accuracy of 100% for the RFID wand device. Despite this engineering success, the possibility of human error and retained sponges remains because handheld scanning can be performed incorrectly.

All Publications button
1
Publication Type
Journal Articles
Publication Date
Journal Publisher
Archives of Surgery
Authors
Alex Macario
Paragraphs

Background:

There is increased interest in quantitative ultrasound for osteoporosis screening because it predicts fracture risk, is portable, and is relatively inexpensive. However, there is no consensus regarding its accuracy for identifying patients with osteoporosis.

Purpose:

To determine the sensitivity and specificity of calcaneal quantitative ultrasound for identifying patients who meet the World Health Organization's diagnostic criteria for osteoporosis. Dual-energy x-ray absorptiometry (DXA) was used as the reference standard.

Data Sources:

MEDLINE (1966 to October 2005), EMBASE (1993 to May 2004), Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews (1952 to March 2004), and the Science Citation Index (1945 to April 2004).

Study Selection:

English-language articles that evaluated the sensitivity and specificity of calcaneal quantitative ultrasound for identifying adults with DXA T-scores of -2.5 or less at the hip or spine.

Data Extraction:

Two authors independently reviewed articles and abstracted data.

Data Synthesis:

The authors identified 1908 potentially relevant articles, of which 25 met the inclusion criteria, and calculated the sensitivity and specificity of quantitative ultrasound over a range of thresholds. For the quantitative ultrasound index parameter T-score cutoff threshold of -1, sensitivity was 79% (95% CI, 69% to 86%) and specificity was 58% (CI, 44% to 70%) for identifying individuals with DXA T-scores of -2.5 or less at the hip or spine. For a T-score threshold of 0, sensitivity improved to 93% (CI, 87% to 97%) but specificity decreased to 24% (CI, 10% to 47%). At a pretest probability of 22% (for example, a 65-year-old white woman at average risk), the post-test probability of DXA-determined osteoporosis was 34% (CI, 26% to 41%) after a positive result and 10% (CI, 5% to 12%) after a negative result when using a T-score cutoff threshold of -1. Analysis of other quantitative ultrasound parameters (for example, broadband ultrasound attenuation) revealed similar estimates of accuracy.

Limitations:

The relatively small number of included studies limited the authors' ability to evaluate the effects of heterogeneous study characteristics on the diagnostic accuracy of quantitative ultrasound.

Conclusions:

The currently available literature suggests that results of calcaneal quantitative ultrasound at commonly used cutoff thresholds do not definitively exclude or confirm DXA-determined osteoporosis. Additional research is needed before use of this test can be recommended in evidence-based screening programs for osteoporosis.

All Publications button
1
Publication Type
Journal Articles
Publication Date
Journal Publisher
Annals of Internal Medicine
Authors
Douglas K. Owens
Subscribe to Science and Technology