The Concurrent Validity and Responsiveness of the Health Utilities Index (HUI 3) Among Patients with Advanced HIV/AIDS

Objectives To assess the concurrent validity and responsiveness of the Health Utility Index 3 (HUI3) in patients with advanced HIV/AIDS, and to determine the responsiveness of this measure, the MOS-HIV and EQ-5D to HIV-related clinical events.

Methods Data from the OPTIMA (OPTions In Management with Antiretrovirals) trial was analyzed. Two aspects of the validity of the HUI3 were considered: concurrent validity was evaluated using Spearman correlations with MOS-HIV component and summary scores. Responsiveness to AIDS-defining events (ADE) and all adverse events (our external change criterion) was assessed using area under the receiver operating characteristic (AUROC) curves.

Results The study enrolled 368 patients (mean follow-up: 3.66 years); 82% had at least one severe adverse event and 27% had at least one ADE. The HUI3 scale and items showed good concurrent validity, with 85% of the expected relationships with the MOS-HIV subscales verified. The HUI3 was responsive to both adverse events (AUROC [95%CI]: 0.68 [0.57, 0.80]) and ADEs (0.62 [0.51, 0.74]). The EQ-5D was responsive to ADEs (0.66 [0.56, 0.76]), but not responsive to adverse events (0.56 [0.46, 0.68]).

Conclusion The HUI3 is a valid and responsive measure of the change in HRQoL associated with clinical events in an advanced HIV/AIDS population.